3 feet in any direction horizontally or vertically to the feature.
Gas regulator in attic.
Gas meter regulator vent clearance distance to windows attic vent crawl space vent soffit vent.
The vent hole on a gas regulator is purely to equalise the pressure on the diaphram inside the regulator in respect to atmosphere.
Regulators not equipped with a vent limiting means shall be permitted to be vented either directly to the outdoors or to a point within the top 1 foot 305 mm of the chase.
Gas meter regulator vent clearance to electrical devices such as switches electrical receptacles power disconnects.
Many builders use csst in new construction including installations with pounds pressure delivered to regulators at each appliance.
What s a gas regulator doing in the attic.
Here each gas regulator vent is piped to the exterior wall individually with an approved device peck vent cap or a screened 90 to an approved location.
Basically the air trapped in the void when it was assembled.
If the top of the regulator was sealed then the diaphram inside would resist movement due to there being an increase of pressure resisting against it.
This piping material is flexible so it bends easily to route around bracing or other obstacles and make turns.
Where gas distribution pressure in excess of 1 2 psig 3 4 kpa.
The inspector will or should know the details your plumbing code book fuel gas section may have info on venting gas regulators as well.
Gas meter piping supplying gas to a building at a pressure in excess of 1 2 psig 3 4 kpa gauge shall be provided with a regulator that will reduce the pressure of the gas to 1 2 psig 3 4 kpa gauge or less prior to entering the gas distribution piping in the building except where the use of higher pressure is permitted.
3 feet in any direction to the feature.
The myfire puck an important addition to the gv60 symax south field michi gan july 23 2019 the myfire puck is.
Corrugated stainless steel tubing csst can be installed in the walls or in attic space for natural gas.
Check with a licensed plumber or your building department.
Where the fuel gas is heavier than air the regulator vent shall be vented directly to the outdoors.